Products
GDI Solutions provide the best technology and services in environmental and safety measurements.

Analytical Industires Inc - GPR Series

Suitable for trace oxygen measurements from 0.1 ppm through to purity applications at 100% oxygen, these rugged portable instruments share the same advanced sensor technology as the online process oxygen analyzers ensuring confidence in their reliability and accuracy.

The Analytical Instruments concepts of using the same HMI and menu structures for portable and online analyzers makes it extremely easy for operators to use both types of instruments on their site without need for extra training.

Features and Benefits

  • Rugged design-Proven to last in field operation
  • Easy to use
  • Up to 30 days on a single charge (40 hours with pump running)
  • 0-10 ppm ~ 0-100% O2 Measuring range
  • 24 to 32 months sensor life span
  • Lightweight – 2.5Kg
  • Internal pump option
  • 0-1V output
  • LT sensor options for CO2 background

Specification

GPR-1100 GPR-1000 GPR-2000 GPR-3500MO
Measurement Range 0-10, 0-100, 0-1000 ppm, 0-1%, 0-25% 0-1000 ppm, 0-1%, 0-25% 0-1%, 0-5%, 0-10%, 0-25% 0-100%
Accuracy < 2% of selected range at constant conditions
Response time(T90) T90 < 10 seconds T90 < 13 seconds
Recovery time 60 sec in air to < 10 ppm in < 1 hour on N2 purge 60 sec in air to < 100 ppm in < 15 min on N2 purge NA
Sensitivity (LDL) 0.05 ppm 5 ppm 0.005 % 0.1 %
Linearity < 1% of scale
Sensor model GPR-12-333 GPR-12-333 GPR-12-333 GPR-12-333
XLT-12-333

gases containing > 0.5% CO2

XLT-12-100-M

gases containing > 0.5% CO2

XLT-11-24-RTS

gases containing > 0.5% CO2

Sensor life Within less than 1000 ppm O2 24 months GPR-11-32-RTS: 32 months on standby

XLT-11-24-RTS: 24 months on standby

100% O2 within 24 months
Calibration interval 30 days
Inlet pressure 0.34–2 barg (5-30 psig) with atmospheric vent
Flow rate 0.5-1.0 L/m (1-2 SCFH)
Gas connections 1/8" NPT male quick connect 1/8" quick connect WP 1/8” compression fittings 1/8" compression tube fittings 1/4" compression tube fittings
Wetted parts Stainless steel Brass connections;

stainless steel optional

GP version: stainless steel fittings;

plastic tubing

ATEX version: Stainless steel flow housing, tubing and fittings

Stainless steel
Display Graphical LCD 7 x 3.5cm (2.75 x 1.375”)
Resolution 0.01 ppm 1 ppm 0.001 % 0.1 %
Enclosure Painted aluminum NEMA 4X

10.1 x 22.9 x 7.6cm (4 x 9 x 3”)

Compensation Barometric pressure and temperature
Signal output 0-1 V
LED indication LOW BATT (72 hrs warning); charging mode
Operating temperature 5°C to 45°C (41°F to 113°F) (GPR sensor)
-10° to 45°C (14°F to 113°F) (XLT sensor)
5ºC to 45ºC
(41°F to 113°F)
Power Rechargeable battery (lead acid)
Battery life Up to 30 days when fully charged (40 hrs when running pump) Up to 30 days
Area Classification ATEX: Ex ib IIB T4
Tamb +5°C to +45°C
Multi-purpose only