FGD FlameSpec IR3 H2 flame detector
FlameSpec-IR3-H2 flame detector provides ultra-fast response, high performance, and reliable detection of hydrogen fires. It operates in all weather and light conditions with the highest immunity to false alarms. These features, along with the built-in event logger, provide additional means to study the cause and development of fire events for "lesson learned" reviews.
Features and Benefits
- High immunity to false alarm
- Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection
- High sensitivity – up to 100 ft. (30m)
- Data/Event logger – alarms, faults and other relevant events are logged to non-volatile memory
- Built-in-Test(BIT) – Automatic and manual internal self-test of window cleanliness and the overall operation of the detector
- Window heater to avoid condensation and icing
- Stainless Steel Tilt mounting bracket can be connected either above or below the detector
- ATEX/IECEx/FM/DNV certifications
- SIL2 certification
Specification
Category | Item | Description |
---|---|---|
Fire Detection | Detection time and distance |
40ms for fast fire burst or explosion 1.5s 4s for 32" (0.8m) hydrogen fire at 0–66 ft. (0–20m) for 32" (0.8m) hydrogen fire at 66–100 ft. (20–30m) |
Field of View (IR detection) | 90° Horizontal, 75° Vertical | |
Time Delay | Configurable 0-30 seconds | |
Built in Test | Automatic and Manual | |
Electrical Specifications | Operating Voltage | 24 VDC nominal (18-32 VDC) |
Current Consumption |
Standby: 120mA 180mA all systems in operation (Including window heater) |
|
Electrical Entries | 2x cable and conduit entries 3/4" NPT(F) or M25x1.5 | |
Wiring | 12-20AWG (2.5-0.35mm2) | |
Outputs | Relays |
SPST volt-free contacts rated 2A at 30 VDC 3 relays: Alarm & Auxiliary – normally open; Fault – normally closed |
0-20mA (stepped) current output |
3 wire and 4 wire (isolated) configurations (sink and source) HART® rev 7.0 (option available) |
|
Indication | Tri-color LED (Green, Yellow, Red) | |
Modbus | RTU compatible on RS-485 | |
Mechanical Specifications | Size | 5.51 x 3.54 x 3.54″ (140x90x90mm) |
Weight |
Detector (Stainless Steel 316): 6.6 lbs. (3.0 kg) Tilt mount (Stainless Steel 316): 3.3 lbs. (1.5 kg) |
|
Environmental Specifications | Temperature Range |
Operating: -67°F to +185°F (-55°C to +85°C) Storage: -67°F to +185°F (-55°C to +85°C) |
Humidity | Up to 99% (RH), non-condensing | |
Ingress Protection | IP66 & 68(2m, 24hr); NEMA 4X & 6P | |
Approvals | ATEX |
ATEX : II 2 G D Ex db IIC T5 Gb or Ex db eb IIC T5 Gb and Ex tb IIIC T95°C Db -55°C < Ta < 75°C Ex db IIC T4 Gb or Ex db eb IIC T4 Gb and Ex tb IIIC T105°C Db -55°C < Ta < 85°C |
IECEx, INMETRO & PESO |
Ex db IIC T5 Gb -50°C≤Ta≤75°C Ex db IIC T4 Gb -50°C≤Ta≤85°C |
|
FMus & FMc |
Class I, Div. 1, Groups B, C & D; T4 Class I, Zone 1, AEx/Ex db IIC T4 Gb T4 -50°C≤Ta≤85°C T5 -50°C≤Ta≤75°C |
|
EAC CU TR |
1Ex d IIC T5 Gb or 1Ex de IIC T5 Gb and Ex tb IIIC T95°C Db -55°C≤Ta≤75°C 1Ex d IIC T4 Gb or 1Ex de IIC T4 Gb and Ex tb IIIC T105°C Db -55°C≤Ta≤85°C |
|
Performance | ANSI FM 3260 | |
Functional safety | Complies to SIL2, per IEC 61508 (option available) | |
Accesories |
Stainless steel weather cover, model FLS-WCO-S01 Flame simulator, model FLS-FSIM-IR3-H2-KIT 2" & 3" pole mount adapter, model FLS-PMA-S23 Airshield for areas with high airborne contamination, model FLS-ASD-S01 |
|
Warranty | 5 years |