MSR-Electronic PolyGard® WSB2 non-explosion proof fixed gas detector

PolyGard® WSB2 is a fixed gas detector that senses oxygen, toxic gases, flammable gases, and vapors in spaces without danger of explosion and provides diverse output signals.

The microprocessor-based gas sensor with 4-20 mA output signal and alarm or fault relay is used to monitor the ambient air for combustible gases and vapors by means of a catalytic sensor element. For sensors without LC display, calibration is performed using the handy STL06-PGX2 calibration device or the PC software PCE06-PGX2. Sensors with LC display have an integrated calibration routine that is started from the outside with a permanent magnet without opening the housing. For sensors with LC display the background lighting changes from green to red in the event of an alarm or error.

Features and Benefits

  • EC, CAT, IR sensors
  • Standard 4~20mA analog output, RS485 Modbus, Relay
  • Up to 3 different gas sensors can be connected simultaneously
  • Self-Test
  • Three-color lamps and a buzzer based on device status(Optional)
  • Plug-in sensor
  • Remote sensor connection (up to 5 meters)
  • Use of oxygen sensor up to 7 years
  • Convenient maintenance
  • Options for AC or DC power
  • UL61010, EN50271 certified

Product Specification

Category Description
Size Type A: 94(W) x 130(H) x 57(D) mm / Type C: 130(W) x 130(H) x 75(D) mm / Type E: 130(W) x 130(H) x 99(D) mm / Sensor: 24(D) x 22(H) mm
Weight about 330g
Material Polycarbonate
IP Rating IP65
Welding connector Type A: 2 x M12 or 3 x M20 / Type C&E: 6 x M20 or M25
Terminal Screw type terminal, 0.25 ~ 2.5 mm²(power), 0.25 ~ 1.3 mm²(signal)
Display 2 x 16 characters, 2-color LEDs
Temperature -30 ~ +60℃(depending on the sensor)
Humidity 20 ~ 90%RH(non-condensing)
Power supply 24Vdc+/-20%, 310mA or 100-240Vac, Max.25VA
Buzzer and Lamp 85dB at 0.1m, 3-color LEDs(Option)
Output Analog: 4~20mA(3-wire system) / Relay: AL/Fault, 30VAC/DC 0.5A / Digital: RS485 Modbus
Certifications EMC directives 2014/30/EU / CE EN 61010-1:2010 / EN 50271 / ANSI/UL 61010-1 / CAN/CSA-C22.2 No. 61010-1

SC2 Sensor Specification

Gas Measuring range Sensor Resolution
CH4 0-100 %LEL IR 0.1 %LEL
CH4 0-100 %Vol IR 0.1 %Vol
C3H8 0-100 %LEL IR 0.1 %LEL
CO2 0-5 %Vol IR 0.001 %Vol
CO2 0-10 %Vol IR 0.01 %Vol
CO2 0-5000 ppm IR 1 ppm
CH4 0-100 %LEL CAT 0.1 %LEL
C3H8 0-100 %LEL CAT 0.1 %LEL
C3H8 0-30 %LEL CAT 0.01 %LEL
C3H8 0-5000 ppm CAT 1 ppm
HC 0-100 %LEL CAT 0.1 %LEL
O2(2, 3year lifespan) 0-25 %Vol EC 0.01 %Vol
O2(5, 7year lifespan) 0-25 %Vol EC 0.01 %Vol
CO 0-150, 250, 300, 500 ppm EC 0.1 ppm
H2S 0-50 ppm EC 0.01 ppm
H2S 0-100, 200, 500 ppm EC 0.1 ppm
H2S 0-1500 ppm EC 1 ppm
NH3 0-100, 300, 500 ppm EC 0.1 ppm
NH3 0-1000, 5000 ppm EC 1 ppm
NO2 0-100 ppm EC 0.1 ppm
HCN 0-50 ppm EC 0.01 ppm
HCN 0-100 ppm EC 0.1 ppm
HCl 0-20 ppm EC 0.01 ppm
Formaldehyde 0-100 ppm EC 0.01 ppm
Ethylene 0-200 ppm EC 0.1 ppm
O3 0-5 ppm EC 0.001 ppm
O3 0-10 ppm EC 0.01 ppm
Cl2 0-10, 20 ppm EC 0.01 ppm
SO2 0-20 ppm EC 0.01 ppm
Ethylene oxide 0-10 ppm EC 0.01 ppm